Liquid Dynamics International Ltd. - Piping System Analysis / Piping System Simulation

LDi – P23

"Witchcraft and Black-boxery"; No, the LDi difference is:
1. Everything is seen in hard copy
2. In real time, large black and white
3. From certified pressure calibrated transducers.

Witch-Doctor

Can You See It?
We agree with the skepticism, "you can make computer data say anything". We have even been shown so called pressure traces form totally different systems, to those under examination.
When it goes directly into a computer, you have no validation proof.
Oscilloscopes are fine, however when you have to play back to make a comparison, the operator thinks he can get away with showing you anything. There is only one solution. Hard copy, not just hard copy but high paper rate copy. Copy where a full 110 mm width can be allocated to one of multiple channels, where the paper streams out at not less than 200 mm per second, 8 dots per mm, and 250 kHz real time.
In street language that means you can see evidence of events which occur in 0.65 of a millisecond, or you can clearly see 1000 + Hz activity.
The point is that now you have original detailed hard copy, playbacks are easily identifiable and valid at any scale, making truly substantial analysis possible.

Can It Be Detected?
When one dot = 5 "mil" 5/1000th of an inch or 0.125 mm and is equal to 0.00065 seconds, it is essential to take a sample or reading more frequently. Unless the transducers have suitably responsive characteristics, all the best capture and printing, will be worthless.
A suitable transducer specification is:
A. Certified calibrated and with accuracy - including linearity, hysteresis and repeatability to 0.5% FSO
B. Frequency response up to 10kHz
C. 10 Volt DC out
Then from the oscillograph to the computer an IEEE488.1 or similar, parallel interface with a transfer rate of not less than 1 Megabyte per second. All used with signal conditioners of 5 kHz response.
It is easy to hide events and claim success before and after, when one shows pressure before, then flow after.
Typically disguised signals by poor equipment and long time base.

Which-Analyst

There are analysts who specialize in building electrical systems of resistances, applying an AC sine wave, and calling it a simulation of a pipe system. There are step functions or discontinuities that are essential to understanding liquid mass transfer that this method neglects to simulate.
There are specialists who will instrument your system, stream the data onto a local computer, drag the data into their own computer periodically, via the internet, and apply "triggering software" to alert them to abnormalities. They will call you days in advance to alert you to a valve going bad.
Then there are those, who believe that data capture of noise, is literally as good as experienced ears and a stethoscope.
LDi are not in any of these categories. We believe in displaying and explaining enough for you so that you will not need us in the future. Adding to the understanding of systems is our purpose.

Take your pick

The base time of each is 0.020 seconds they are the same event