LDi – P42

Typical values of "Z" for reciprocating sine motion driven machines.

1 For simplex (Single piston, plunger, or maybe reciprocating oil to move a diaphragm)
2 For duplex (Two plungers, etc. Flow still comes to a halt as one displacer takes over from the
other)
4 For triplex (Three plungers, etc. Flow still comes to a near halt unless the volumetric efficiency is well above 75%)
6.5 For quadruplex (Four plungers, etc. phased at 90 - Sounds better, but chances of resonance
are worse)
9 For Quintuplex (Five displacers, overlap even with hot compressible liquids at high pressure)
18 For Septuplex (Seven displacers, smoother flow than a "Quin", but the frequency is high and
may match the natural vibration frequencies or the acoustic or the mass oscillation frequencies of short pipe nodes)

For two displacers or more where the drive is a linear oscillation, from fluid power, the value for "Z" may be more than doubled. How much more, depends on the dwell that occurs on direction changeover. This is more affected by drive fluid compressibility than valve design.

Two Examples

In these two examples, the pumped flow rate, stays the same, the "jerk-rate" - number of modulations per minute, and everything else stay the same, except pipe length " L".

The formula is from general industry use by Milton Roy and Foster Wheeler, etc. The "Z" factors are modified from empirical experience since 1963.

Note: increased pipe length gives more pulsation. Therefore, pulsation depends on the system. Similarly, changing the density of the liquid or the diameter of the pipe will change the pulsation.

Pumps make flow, but systems make pressure, pressure pulsation is a system response to flow fluctuation, and a system responsibility, not a pump vendor liability. Nor is the pump vendor necessarily qualified to address system piping and valve response pressure pulsation. Please call 1-888-DAMPERS, not the pump vendor.

Note:
As pulsation depends on pipe system length, diameter and the specific gravity of the system liquid, determining a dampening need without taking system details into consideration, is likely to lead to a less than suitable specification.